ALIGNMENT PROCEDURE


CPU and Phase Locked Loop Section


Test equipment required:
Power Supply: 13.2 VDC Volt MeterOscilloscope
Frequency Counter

StepSettingConnectionAdjustAdjust for
1Frequency adjustment
Mode: Receive
Volume: Optional
Squelsch: Optional
Channel: 1
Frequency counter to IC5 Pin 1CT9014.5 MHz +- 100 Hz
2CPU Voltage Check
Mode: Receive
Volume Optional
Squelsch: Optional
Channel: 40
Connect DC Volt Meter to TP1T100Indication on DC Volt Meter must be 4.8 to 5.2 Volt


Receiver Section


Test equipment required:
Power Supply: 13,2 VRF Signal GeneratorSSVM Sinad MeterAudio Generator
AF Power MeterAF Distortion Meter8 ohm Load

StepSettingConnectionAdjustAdjust for
1RX Sensitivity
Mode: Receive
Volume: Fully clockwise
Squelch: Turn to clockwise
Channel: 19
SSG: 27.185 MHz, 1 uV(-107 dBm), AM 30% modulation
Connect RF Signal Generator to external ANT-jack. Connect SSVM Sinad Meter and Distortion Meter across External speaker out jack with 8 ohm dummy load.T501
T502
T504
T503
Adjust the parts of tuning circuit with observing AMD (AutomaticDisMeter) indicates 20 dB SINAD in AM-mode, and adjust output level of RF-SSG until speacker output level reaches about 500 mWatt (2.0 Volt)
2RX Sensitivity
Mode: Receive
Volume: Fully clockwise
Squelch: Turn to clockwise
Channel: 19
SSG: 27.185 MHz, 1 uV(-107 dBm), AM 30% modulation
Connect RF Signal Generator to external ANT-jack. Connect SSVM Sinad Meter and Distortion Meter across External speaker out jack with 8 ohm dummy load.T001Adjust for maximum indication on SSVM.
3Squelch adjustment
Mode: Receive
Squelch: Tight
Channel: 19
SSG: 27.185 MHz
1 kHz mod., 2,815uV (-47dBm), 30% mod.
Connect RRF SSG to ANT-jack. Connect AF Power Meter and Distortion Meter across ext-speaker with 8 ohm dummy-loadVR501At each mode, Adjust the point until the audio appeared on oscilloscope
4Signal meter adjustment
Mode: Receive
Volume: 500 mWatt
Squelch: Counterwise
Channel: 19
SSG: 27.185 MHz, 100 uV (-67 dBm), No mod.
Connect RF signalgenerator to external ANT-jack. Connect AF Power meter and Distortion Meter across external speaker jack with 8 ohm dummy load.VR301Adjust so that the 9`th LCD-Bar display on the LCD-meter.


Transmitter Section


Test equipment required:
Power Supply: 13,2 VRF Power MeterOscilloscopeAudio Generator
Frequency CounterSpectrum Analyzer50 ohm Load

StepSettingConnectionAdjustAdjust for
1RF Driver stage
Mode: Transmit
Volume: Optional
Squelch: Optional
Channel: 19
Connect Oscilloscope to base of Q602T601
T602
Adjust for maximum wave-form on the oscilloscope
2RF Power stage
Mode: Transmit
Volume: Optional
Squelsch: Optional
Channel: 19
Connect dummy-load and RF Power-meter to external ANT-jackT604Adjust for maximum indication on the RF Power-meter
3Second harmonic check
Volume: Optional
Squelch: Optional
Channel: 19
Connect RF Power-meter with dummy-load to spectrum analyzerAt no modulation compare the level of fundamental freq-spectrum to the level of harmonic freq-spectrum.
Supression of the 2nd harmonic freq. level must be lower than -54dBm.
4Frequency check
Mode: Transmit
Volume: Optional
Squelch: Optional
Channel: 19
Connect dummy-load and Frequency-counter to ANT-jack.CT901Make sure that the indication of the transmit frequency is 27.185 MHz +/- 300 Hz.
5Max. modulation check
Mode: Transmit AM
Volume: Optional
Squelch: Optional
Channel: 19
Connect dummy-load and Modulation-meter to ANT-jack.VR401Adjust so that the indication of the Modulation-analyzer is 90% with +/- 5% tolerance at high power mode.
6Max. deviation check
Mode: Transmit FM
Volume: Optional
Squelch: Optional
Channel: 19
Connect dummy-load and Modulation-meter to ANT-jack.VR401Adjust so that the indication of the Deviation-analyzer is 2 kHz with +/- 0,2 kHz tolerance at high power mode.


This counter shows the number of hits since the 7th November 1999


Go Back To The Alignments Page

Go Back To The Main Home Page

Copyright © RadioMods 1997-2016

https://www.radiomods.co.nz/